CFLCC - 10578, CODE 1842-411
- MSDS: CFLCC
- Manufacturer: QUALCHEM COMPANY
- Product Name: 10578, CODE 1842-411
- National Stock Number: 6850-00-174-9672
Product Identification
Product ID:10578, CODE 1842-411
MSDS Date:11/01/1995
FSC:6850
NIIN:00-174-9672
MSDS Number: CFLCC
Responsible Party
BELLEVILLE, NJ 07108
US
Emergency Phone: 201-759-0105
Info Phone: 201-759-0105
Preparer: SIGNATURE NOT READABLE
Cage: 07XT7
Contractor
Telephone: 201-842-1307
Cage: 07XT7
Ingredients
CELLOSOLVE OR 2-ETHOXYETHANOL (SARA 313) (CERCLA)
CAS: 110-80-5
RTECS: KK8050000
Fraction By Weight: 11%
OSHA PEL S, 200 PPM
ACGIH TLV: S, 5 PPM; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PHOSPHORIC ACID (SARA 313) (CERCLA)
CAS: 7664-38-2
RTECS: TB6300000
Fraction By Weight: 71%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3/3 STEL; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
NONIONIC SURFACTANT OR POLYOXYPROPYLENE GLYCOL
CAS: 9003-11-6
RTECS: MD0911050
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Hazards
LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOSURE MAY CAUSE SKIN & EYE
IRRITATION; MAY CAUSE BURNS, DERMATITIS, AGGRAVATE EXISTING SKIN
CONDITIONS. INHALATION MAY CAUSE CNS EFFECTS. ASPIRATION WHEN
SWALLOWING OR VOMITING MAY CAUSE LUNG DAMAG E. INGESTION MAY CAUSE
BURNS TO DIGESTINVE TRACT. CHRONIC EFFECTS: UNKNOWN.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:EYE-IRRITATION, BLURRED VISION.
SKIN-IRRITATION, BURNS, DERMATITIS. INHALATION-HEADACHE, DIZZINESS,
ANESTHETIC & OTHER CNS EFFECTS. INGESTION-SMALL AMOUNTS MAY BE
DRAWN INTO LUNGS & MAY CAUSE BURNS & INFLAMATION; MAY BURN G/I
TRACT.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING SKIN
CONDITIONS.
First Aid
First Aid:GET IMMEDIATE MEDICAL ATTENTION. INHALATION-REMOVE TO FRESH
AIR. GIVE OXYGEN AS NEEDED. EYE-FLUSH W/PLENTY OF WATER. SKIN-WASH
W/SOAP & WATER. REMOVE CONTAMINATED CLOTHING. INGESTION-GIVE
SEVERAL GLAS SES OF WATER. DO NOT INDUCE VOMITING. NOTE TO
PHYSICIAN-PRODUCT IS AN INDUSTRIAL DEGREASER WHICH CONTAINS SOAP &
GLYCOL ETHERS.
Fire Fighting
Autoignition Temp:Autoignition Temp Text:NA
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: USE MEDIA
APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: WEAR
SELF-CONTAINED BREATHING APPARATUS AND FULL FIRE FIGHTER'S
PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:LARGE SPILLS-SOAK UP W/SAND OR SWEEPING
COMPOUNDS & DISPOSE AS A SOLID. FOR SMALL SPILLS USE AN INDUSTRIAL
SEWER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:NONE.
Exposure Controls
Respiratory Protection:NONE NEEDED UNDER NORMAL CONDITIONS.
Ventilation:ENGINEERING CONTROLS:STORE IN A COOL, DRY PLACE.
Protective Gloves:RUBBER GLOVES
Eye Protection:FACE SHIELD OR SAFETY GLASSES.
Other Protective Equipment:MFR GAVE NO INFORMATION OF MSDS.
Work Hygienic Practices:MFR GAVE NO INFORMATION OF MSDS.
Supplemental Safety and Health
NONE.
Chemical Properties
HCC:C1
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.612
pH:>1.0
VOC Grams/Liter:1.8
Viscosity:2.3 CPS
Evaporation Rate & Reference:1.2 (WATER = 1)
Solubility in Water:COMPLETE
Appearance and Odor:WATER WHITE LIQUID; MILD ODOR.
Percent Volatiles by Volume:90
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI, REDOX AGENTS, ALUMINUM FINES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON, PHOSPHORUS.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.